id4u

Welcome Welcome to our website

Sponsored Links





Premium Advertisement

Premium Advertisement

Premium Advertisement

Premium Advertisement

Rawatan Anti Kulat & Anti Bakteria Pada Bangunan & Hospital

RAWATAN ANTI KULAT & ANTI BAKTERIA PADA BANGUNAN & HOSPITAL ~ Price : MYR 0


88 clicks
Advertiser ID : Yusri Bin Maskon
Contact No : 60173387920
Ads Category : Services
Update : 17-12-2018
Follow Us :
Location : Kuala Lumpur




Description :

PERKHIDMATAN RAWATAN ANTI KULAT , ANTI BAKTERIA DAN ANTI KONDENSASI PADA DINDING BANGUNAN PEJABAT, HOSPITAL DAN SISTEM PENDINGIN UDARA

PERKHIDMATAN RAWATAN ANTI KULAT , ANTI BAKTERIA DAN ANTI KONDENSASI PADA DINDING BANGUNAN PEJABAT, HOSPITAL DAN SISTEM PENDINGIN UDARA

PERKHIDMATAN RAWATAN ANTI KULAT , ANTI BAKTERIA DAN ANTI KONDENSASI PADA DINDING BANGUNAN PEJABAT, HOSPITAL DAN SISTEM PENDINGIN UDARA

FNR Indoor Environmental (FNR). Experienced in its field of service since 2001 by a group of ambitious and experience professionals in their own fields of expertise in promoting the needs for “Indoor Air Quality” (IAQ). Good IAQ is required for a healthy indoor working environment while poor IAQ can cause various discomfort and illness to the tenants. With our depth knowledge and experience in IAQ services, we strongly believe can provide a better and healthier IAQ to all type of buildings and infrastructures such as office buildings, hospitals, industrials, oil & gas industry, ships and many others.

We offer the latest technology and reliable method in enhancing the quality of IAQ through proper monitoring system, treatment & services of HVAC system, “AC Duct cleaning” & treatment and Anti Microbial service & treatment.. Our services will comply with all guidelines and policies with regards to Indoor Air Quality, Occupational Safety & Health and Environmental issues and Malaysian Society for Quality  in Health (MSQH). Service provided as follows :

  • “Ac Duct cleaning” and treatment.
  • Air Handling Unit cleaning and treatment.
  • Internal insulation replacement.
  • Treatment and “sanitization” of bacteria,fungus and mold.
  • “Anti Condensation” solution and treatment .
  • “Kitchen” system cleaning and treatment.
  • “IAQ” and “NEBB” related test and inspection.
  • Anti Bacterial fogging services.
  • HVAC system Air balancing.
  • All type of Air Purifier, UV light & filter solutions.

 

Our AC Duct cleaning and treatment process use the latest equipment such as the “Robotic” cleaning system, “Compressed Air Nozzle” cleaning system and also the “Brush” cleaning system. You can also see our services at the following link : https://www.youtube.com/watch?v=TZLMtyujCgo

For further enquiry, kindly contact@whatsapp me (Yusri) at +6017-3387920 / +601120727900 / yusri_fnr@yahoo.com.

 FNR INDOOR ENVIRONMENTAL

NO 20, JALAN BATU MUDA TAMBAHAN 5,

KAMPONG BATU MUDA TAMBAHAN, 51100 KUALA LUMPUR

Tel : +603-61852303/0203, Fax : +603-61852308, HP : +60173387920

Email : fnrcons@yahoo.com ,

GENERAL TECHNICAL SPECIFICATION FOR AC DUCT CLEANING & TREATMENT

  1. Method of Cleaning. Contractor must use the Robotic Cleaning System and Air Compressed Nozzle Cleaning System during the cleaning of the following ducts;
  2. Robotic Cleaning Systems. All ‘Main Duct’ and ‘Flat Duct’ must be cleaned using the Robotic Cleaning Systems including the fresh and return duct. Additional vital robotic specification as schedule of technical requirement.
  3. Air Compressed Nozzle Cleaning System. Flexible Duct, Vertical Duct, small and all un-accessible duct by robotic system must be cleaned by the Air Compressed Nozzle Cleaning system. Additional vital air compressed nozzle specification as schedule of technical requirement.

Safety of equipment as not to disturb , damage to other properties and inhabitants of the building shall be observe by the contractor. All debris including dirt resulting the services must be cleaned. A new access door at the Duct must be installed if new entrance to the Duct is required during the services.

  1. Sanitization and Treatment Exercise. The contractor shall sanitize the entire air duct interior of the air conditioning system with anti bacterial sanitizer after the cleaning exercise by using the robotic 360 degrees rotating fogging machine. The chemical sanitizer must be able to reduce and effectively against a broad spectrum of microorganism, It also shall eliminates odour and non-toxic. Should there be cleaning of coil , diffusers and grills are required, the use of alkhaline based chemicals is required to prevent corrosion .Warranty of such treatment and free from microorganism is for six (6) months after applying the chemical. Other vital requirement of the said chemicals as schedule of technical requirement and the said MSDS must be submitted during tender process.
  2. Swab Test Sampling. Microbial growth samples are taken as outlined in the above procedure. Upon confirmation that the growth rates have been reduce to acceptable levels ( based on the laboratory analysis of ventilation air and exposure to occupant), for the specified area is deemed completed. Swab sampling test are taken for “Before” and “After” the services. The contractor shall take swap test at a specified location as per the BQ to a Third Party accredited laboratory. Third party accredited laboratory vital requirement as schedule of technical requirement.
  3. Microorganisms/Swab Testing Laboratory. All third party laboratory testing must be done by a certified ISO and Skim Akreditasi Makmal Malaysia (SAMM) laboratory. The contractor shall submit Letter of Support from Accredited Laboratory together with all the relevant certification of the said laboratory. Upon completion of testing, the said laboratory to submit laboratory status report and “Letter of Service and Compliance’ complying the requirements of Malaysian Industrial Code of Practice on Indoor Air Quality 2010 (MICOP – IAQ 2010)
  4. Inspection of Services. All inspection should be done at all duct before and after the cleaning process to check the existing condition of the duct including damages , dirts , debris and other visible items. All physical damages will be reported immediately to the SO before work commence. Inspection process will also be done during the cleaning process when required by the SO should there be any clarification. All inspection must be done by robotic system and manual inspection should the duct is not accessible by the robot systems.
  5. Filtering Process. The contractor must provide filtering element or vacuuming device during the cleaning to filter all the dusk and dirt . The filter/vacuum must be able to trap all dusk and dirt from falling or spreading on the said building floor. Vital requirement for filtering or vacuuming specification as schedule of technical requirement.
  6. Video and Photo Recording of Duct Cleaning Exercises. The contractor shall video recorded and take photos of the HVAC system cleaning process of BEFORE, DURING and AFTER cleaning and hand over to client. The contractor shall also take photos the cleaning process and submit it over to client during final reporting.
  7. As Built Drawing of AC Duct System. The contractor is to submit the technical drawing for the Duct system upon completion of the service for the existing building. All drawing must be prepared and endorsed by a certified engineer (Ir). Other drawing requirement must be discussed later with the appointed SO.

For further enquiry, kindly contact@whatsapp me (Yusri) at +6017-3387920 / +601120727900 / yusri_fnr@yahoo.com.



RAWATAN ANTI KULAT & ANTI BAKTERIA PADA BANGUNAN & HOSPITAL


Keywords Tags: RAWATAN KULAT | RAWATAN BAKTERIA | RAWATAN FUNGUS | RAWATAN KULAT | RAWATAN ANTI KONDENSASI




Disclaimer
This advertisement and the information related to it are provided and maintained by the advertiser. id4u.my is not responsible and can not guarantee the accuracy or completeness of this advertisement.


Sponsor Ads

1000 clicks


Ads By Google

MYR 170

105 clicks

Produk Dalaman Wanita Paling Berkesan I 60126764118

MYR 36

219 clicks

Vip Drinks "fresh Coconut Water" "fresh Coconut Water" 7

MYR 99

53 clicks

Al Raisha Selection And Beauty Care I 60126764118

MYR 0

90 clicks

Kereta Myvi Sewa Sg Buloh | 013 612 6060

MYR 000

36 clicks

Ultimate 7 Fat Burner 601111983461

SGD 0

18 clicks

Course For Malay Language Singapore|edureach

USD 90

54 clicks

Range Rover Body Kit

MYR 000

77 clicks

Myetherpony Japan China Hong Kong Korea Malaysia & Vietnam

MYR 139

302 clicks

Produk Kurus Paling Berkesan 2017

MYR 00

225 clicks

Iklan Ke 1st Page Google

MYR 10

38 clicks

Air Freshener Bertam

Sponsored Links

Latest Advertisement

Premium Advertisement

Premium Advertisement



Most Popular